国产av成人精品播放,中文成人无码精品久久久不卡,国产91在线精品福利,久久综合精品不卡一区二区,成人在线免费视频ww,福利网站导航,精品欧美一区二区三区四区,视频一区二区三区福利在线
      Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
      Position首頁 > Home > Industrial Safety Products > Safety Controller > Force-guided Safety Relay
      G6SA strong conductance relay


      G6SA-4A2B safety relay (relay with forced guide contact)
      圖片11.png

      ·Four groups normally open+two groups normally closed

      ·Force-guided contact structure (conforming to IEC 61810-3 standard)

      ·Strong load capacity: 6A contact switching ability

      ·Low input power consumption: 500mW

      ·Strong insulation capability: input-output bears 10kV surge voltage.

      ·UL insulation grade: f insulation grade is available for selection.


      Product selection

      product name

      model

      Contact form

      brand

      safety relay

      G6SA-4A2B

      4NO+2NC

      LHS

      explain



      Contact parameters

      Contact form

      4NO+2NC

      Structure classification (according to IEC 61810-3)

      Class a compulsory guidance

      Contact resistance (1)

      100mΩ (1A 6VDC)

      Contact material

      AgSnO2

      Contact load (resistive)

      6A 250VAC / 30VDC

      Maximum switching voltage

      400VAC / 30VDC

      Maximum switching current

      6A

      Maximum switching power

      1500VA /180W

      Electrical durability

      1×105 times (1NO:6A 30VDC, resistive load, room temperature, 1s on and 9s off)

      1×105 times (1NO:6A 250VAC, resistive load, room temperature, 1s on and 9s off)

      Mechanical durability

      1×107次


      Coil parameters

      Rated coil power

      約500mW


      Coil specification sheet

      Rated voltage VDC

      Operating voltage VDC(1)

      Release voltage VDC(1)

      Maximum voltage (2)VDC

      Coil resistance ω

      6

      ≤4.5

      ≥0.6

      6.6

      72×(1±10%)

      9

      ≤6.8

      ≥0.9

      9.9

      162×(1±10%)

      12

      ≤9.0

      ≥1.2

      13.2

      288×(1±10%)

      18

      ≤13.5

      ≥1.8

      21.78

      648×(1±10%)

      24

      ≤18.0

      ≥2.4

      26.4

      1152×(1±10%)

      36(3)

      ≤27.0

      ≥3.6

      39.6

      2592×(1±10%)

      48(3)

      ≤36.0

      ≥4.8

      52.8

      4608×(1±10%)

      Remarks:

      (1) The above values are all initial values;

      (2) The maximum voltage refers to the maximum voltage that the relay coil can bear in a short time;

      (3) For products with rated voltage ≥36V, in order to protect the coil from damage, it must be inhibited in testing and application.

      Measures to generate over-voltage in the coil (such as connecting diodes in parallel with the coil).


      performance parameter

      insulance

      1000MΩ (500VDC)

      Dielectric withstand voltage

      Between coil and contact

      4000VAC 1min

      Disconnect contact

      1500VAC 1 min

      Contact group

      2500VAC 1 min (11-12/13-14)

      4000VAC 1 min (others)

      surge voltage

      Coils and contacts

      10kV (1.2/50μs)

      Contact group

      5kV (1.2/50μs)

      Action time (at rated voltage)

      ≤20ms

      Release time (at rated voltage)

      ≤20ms

      Coil temperature rise (at rated voltage)

      ≤70K(The coil driving voltage is 1.1 times Un, the contact current is rated current, and the ambient temperature is 85℃)

      vibrate

      NO/NC: 10Hz ~ 55Hz 1.5mm double-amplitude

      NO: 55Hz ~ 200Hz, 98m/s2

      NC: 55Hz ~ 200Hz, 49m/s2

      lash

      stability

      100m/s2

      intensity

      980m/s2

      creepage distance

      Between coil and contact

      8mm

      Contact group

      5.5mm

      air interstice

      Between coil and contact

      8mm

      Contact group

      5.5mm

      humidity

      5%~ 85% RH

      temperature range

      -40℃~85℃

      Lead-out form

      Printed board type

      weight

      About 23g

      package

      Flux-proof type

      Remarks: (1) UL insulation grade: F and B; (2) The above values are all initial values.


      Outline drawing, wiring diagram and mounting hole size

      outline dimension

      hookup

       外形尺寸圖.png


      接線圖、安裝孔尺寸.png 

      Remarks:

      (1) The dimension tolerance is not indicated for some external dimensions of the product. When the external dimension is ≤1mm, the tolerance is ±0.2mm;; When the outline ruler

      When the inch is between (1 ~ 5)mm, the tolerance is ±0.3mm;; When the overall dimension is greater than 5 mm, the tolerance is ±0.4mm;;

      (2) The dimension tolerance not indicated in the dimension of the mounting hole is 0.1 mm..


      Performance curve

      9.png

      Remarks:

      (1) Test conditions: 1NO terminal, resistive load, 250VAC, room temperature, 1s on and 9s off.

      (2) The above are the typical values of the test.


      Performance curve

      10.png

      Remarks:

      According to IEC61810-1, Appendix B, Table B.3, test, at room temperature, 1NO, 1s on and 9s off.


      Relay matching socket
      G4SA底座.png

      ·The withstand voltage between the coil and the contact is 2500VAC, and the insulation resistance is 1000 mω.

      Can be installed by screws or guide rails.

      Protect the coil with diode to suppress reverse overvoltage.

      With finger protection cover

      Keep and take out the self-contained relay.



      performance parameter

      Socket type

      rated voltage

      rated current

      Applicable voltage of relay coil

      ambient temperature

      twist moment*

      Maximum conductor section size was

      Bolu conductor length

      weight

      remarks

      A6-6Z-C2-D24

      250VAC

      6A

      (6~24)VDC

      -25℃~55℃

      1.0N·m

      2×1.5

      7mm

      約63g

      With indicator light


      Outline drawing, wiring diagram, mounting hole size and circuit diagram

      Overall dimensions: Top view unit: mm

      Wiring Diagram and Installation Hole Size: Top View Unit: mm

      外形尺寸圖.png11.png

      電路圖

      指示燈.png


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh