      Collaborative robot early warning smart fence

                  

      New generation of robots enter the area safety inspection light curtain, which can be divided into three areas to improve production efficiency




      product name

      Product number

      protected area

      Protection length

      Order number

      Area detection safety light curtain

      DM-R-2-3

      3 zones: alarm zone (observation zone), deceleration zone (debug zone), stop zone (danger zone)

      safe distance

      Dm-R-2-3

      Area detection safety light curtain  

      DM-R-2-6

      3 zones alarm zone (observation zone) deceleration zone (modulation zone) stop zone (danger zone)

      Calculation shall prevail

      DM-R-2-6

      Explanation



      Technical performance


               

      Programmability: each beam is independently programmed, and the 6-points can be monitored by the Goldenest Program: continuous monitoring of each beam to detect whether there are objects in the protection field. When a detected object is sent, a safety signal is sent to save costs: according to processing The environment sets the detection distance of the light curtain light spot, which saves costs and can effectively protect personnel from 10mm detection fingers to 100mm detection human dream eaters. Most can be customized and partitioned: the same set of safety light curtains, different resolutions in different sections, and equipment No protected area safety certification



      Security Level


      ? Type 2   - IEC 61496-1-2

      ? Category 2   - ISO/EN 13849-1

      ? PL d  - ISO/EN 13849-1

      ? SIL 2   - IEC 61508

      ? SIL CL 2   - IEC 62601 type2       



      Technical data


      Supply voltage 

      24VDC +/- 5VDC

      Current consumption Tx,Rx (without load) 

      < 10 mA at 30 VDC

      Output

       PNP  (NPN Optional )

      Max. output current 

      50 mA

      Max. capacitive load

      100 nF

      Temperature range operation

       -40 … +60°C

      Polarity protection 

      Yes

      Enclosure rating

      IP65

      Max. ambient light

      100,000 Lux

      Certificates   CE批準中

      CE  Approving




      Safety circuit


                              

      Programming according to the input and output of the safety light curtain The input and output mode can be customized to program up to 6 beam spots 1-2 beam is the alarm zone 2-4 beam is the deceleration zone 4-6 beam stop zone                                                                                                        



      Connection method using Lihong LHS safety module


                              

      The input and output information of SR301 series safety controllers can be selected and can be customized to control three groups of safety light spot signals at the same time.                                                                                     



                

      SR601 series safety controller

      Can simultaneously receive 6 groups of safe light spot signals

      Input and output mode can be customized input: six groups of safety light spot signals for logic programming

      Combine according to the scene


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh