国产av成人精品播放,中文成人无码精品久久久不卡,国产91在线精品福利,久久综合精品不卡一区二区,成人在线免费视频ww,福利网站导航,精品欧美一区二区三区四区,视频一区二区三区福利在线
      Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
      Position首頁 > Home > Industrial Safety Products > Safety interlock switch > Magnetic induction switch
      LMC3-50 series RFID safety door switch

      1706678051308494.pngimage.png

      With detection confidentiality (unique code can be provided)

      ?Strong anti-interference, safety and reliability.

      ?Safety level PLe can be achieved by using safe dual-channel output technology.

      ?Effectively prevent false positives or false negatives, or artificial abnormal triggers.

      ?Can be used with the safety door.


      395181ccb7a771e30162f6415dc922a.png

      Ordering information

      86b9d0315b563dc534da6381bf695f3.png

      Switch model

      Specification

      Output method

      Encoding method

      LMC3-50-40SNT/5M


      4-core direct wiring with dual output
      5M cable


      NPN

      Universal encoding

      LMC3-50-40SN1/5M

      Unique encoding

      LMC3-50-40SPT/5M

      4-core direct wiring with dual output
      5M cable


      PNP

      Universal encoding

      LMC3-50-40SP1/5M

      Unique encoding

      LMC3-50-60JNT/5M

      6-core direct wiring with dual output and cascading 5M cable

      NPN

      Universal encoding

      LMC3-50-60JN1/5M

      Unique encoding

      LMC3-50-60JPT/5M

      6-core direct wiring with dual output and cascading 5M cable

      PNP

      Universal encoding

      LMC3-50-60JP1/5M

      Unique encoding

      395181ccb7a771e30162f6415dc922a.png

      Model Description


      395181ccb7a771e30162f6415dc922a.png

      Technical parameter

      Safty standard

      Mean Time to Dangerous Failure (MTTFd) (years)

      ISO13849-11EC/EN60947-5-1IEC/EN60947-5-3

      ≥30 years

      Safety classification

      Class 4 switch according to IS0 13849-1/suitable for PLe/PL

      Certification

      CE

      Horizontal working distance

      Conduction, min:10mm

      Vertical working distance

      Conduction, min:8mm

      Operating voltage

      24V DC±15%

      Operating current

      150mA

      Response time

      60ms

      The protection grades

      IP65, IP67 (customized)

      Operating frequency

      lHZ

      Working temperature

      -10~+55℃

      Relative humidity

      5%~95%

      Material

      Flame-retardant thermoplastic


      395181ccb7a771e30162f6415dc922a.png

      Shape and installation dimensions

      尺寸圖.pngLMC3-50.png


      395181ccb7a771e30162f6415dc922a.png

      Approach pattern of LMC3-50 switch

      1706679390304986.png1706679459242220.png


      395181ccb7a771e30162f6415dc922a.pngLMC3-50 switch induction distance


      Misalignment deviation

      breakover

      disconnect

      Alignment signal

      Horizontal alignment

      The deviation is within 4 mm in the X direction.Y direction induction 0~10mmY direction induction distance > 25mmLMC3-50.png
      The deviation is > 5mm and < -5mm in the x direction.Not recommended

      Vertical alignment

      The deviation is within 4mm of soil in X direction.Z direction induction distance 0~8mmZ direction induction distance > 23mmLMC3-510.png
      The deviation is > 5mm and < -5mm in the x direction.Not recommended


      395181ccb7a771e30162f6415dc922a.png

      Hookup

      Two-way output with cascade connection diagram

      serial number

      Signal definition

      colour

      explain

      1706680404188780.png

      1

      24V

      palm

      Power supply positive

      2

      0V

      blue

      Negative power supply

      3

      output1

      black

      Safety output 1

      4

      output2

      white

      Safety output 2

      5

      input1

      green

      Cascade input 1

      6

      input2

      yellow

      Cascade input 2


      395181ccb7a771e30162f6415dc922a.pngLegend of connection between RFID switch and safety relay module (dual output)


      接線圖.png



      395181ccb7a771e30162f6415dc922a.png

      RFID switch approach pattern

      Led display

      Signal state

      State description

      input

      output

      The red light is always on.

      Yes/No.

      break

      No actuator or incomplete alignment (universal coding)

      The red light is on for 1 second and then flashes twice (alternately).

      Yes/No.

      break

      No actuator or incomplete alignment (unique code)

      Red light flashing at 4Hz

      effective

      break

      Output overload

      Green light flashes at 1Hz.

      be invalid

      break

      No input signal (dual output is not applicable)

      The green light is always on

      effective

      through

      Induction is normal

      Alternate flashing of traffic lights

      effective

      break

      Label is not registered.


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh