      LMC3-52 magnetic induction safety switch
      圖片1.png

      ·Miniaturized design,(compatible with 30mm aluminum frames) for easy installation.

      ·Adopts redundant internal circuits(dual CPU mutual inspection)and self-diagnostic function.

      ·Intelligent diagnosis and status display:Integrated LED indicators,provide real-time feedback on door switch status and fault information, facilitating quick troubleshooting.

      ·Support series connection of multiple switches(up to 30 switches can be connected),adapting to complex equipment layouts.

      ·The actuator coding function has low-level and high-level settings. It performs self-learning to match the sensor during initial installation. The high level function is unique and non-interchangeable.

      ·Equipped with magnetic latching function,with a magnetic holding force of up-to 15N,which can replace door magnets.


      395181ccb7a771e30162f6415dc922a.png

      Selection catagory

      Configuration type

      Coding type

      Output mode

      Lead wire mode

      Direct outlet

      Cable length

      Model

      Basic function

      Universal coding

      NPN

      Direct outlet

      3M

      LMC3-52-J2-N-Z3

      5M

      LMC3-52-J2-N-Z5

      10M

      LMC3-52-J2-N-Z10

      M12 Connector

      /

      LMC3-52-J2-N-M12

      PNP

      Direct outlet

      3M

      LMC3-52-J2-P-Z3

      5M

      LMC3-52-J2-P-Z5

      10M

      LMC3-52-J2-P-Z10

      M12 Connector

      /

      LMC3-52-J2-P-M12

      Unique coding

      NPN

      Direct outlet

      3M

      LMC3-52-J1-N-Z3

      5M

      LMC3-52-J1-N-Z5

      10M

      LMC3-52-J1-N-Z10

      M12 Connector

      /

      LMC3-52-J1-N-M12

      PNP

      Direct outlet

      3M

      LMC3-52-J1-P-Z3

      5M

      LMC3-52-J1-P-Z5

      10M

      LMC3-52-J1-P-Z10

      M12 Connector

      /

      LMC3-52-J1-P-M12

      Standard

      Universal coding

      NPN

      Direct outlet

      3M

      LMC3-52-B2-N-Z3

      5M

      LMC3-52-B2-N-Z5

      10M

      LMC3-52-B2-N-Z10

      M12 Connector

      /

      LMC3-52-B2-N-M12

      PNP

      Direct outlet

      3M

      LMC3-52-B2-P-Z3

      5M

      LMC3-52-B2-P-Z5

      10M

      LMC3-52-B2-P-Z10

      M12 Connector

      /

      LMC3-52-B2-P-M12

      Unique coding

      NPN

      Direct outlet

      3M

      LMC3-52-B1-N-Z3

      5M

      LMC3-52-B1-N-Z5

      10M

      LMC3-52-B1-N-Z10

      M12 Connector

      /

      LMC3-52-B1-N-M12

      PNP

      Direct outlet

      3M

      LMC3-52-B1-P-Z3

      5M

      LMC3-52-B1-P-Z5

      10M

      LMC3-52-B1-P-Z10

      M12 Connector

      /

      LMC3-52-B1-P-M12

      High-function typle


      Universal coding

      NPN

      Direct outlet

      3M

      LMC3-52-G2-N-Z3

      5M

      LMC3-52-G2-N-Z5

      10M

      LMC3-52-G2-N-Z10

      M12 Connector

      /

      LMC3-52-G2-N-M12

      PNP

      Direct outlet

      3M

      LMC3-52-G2-P-Z3

      5M

      LMC3-52-G2-P-Z5

      10M

      LMC3-52-G2-P-Z10

      M12 Connector

      /

      LMC3-52-G2-P-M12

      Unique coding

      NPN

      Direct outlet

      3M

      LMC3-52-G1-N-Z3

      5M

      LMC3-52-G1-N-Z5

      10M

      LMC3-52-G1-N-Z10

      M12 Connector

      /

      LMC3-52-G1-N-M12

      PNP

      Direct outlet

      3M

      LMC3-52-G1-P-Z3

      5M

      LMC3-52-G1-P-Z5

      10M

      LMC3-52-G1-P-Z10

      M12 Connector

      /

      LMC3-52-G1-P-M12


      395181ccb7a771e30162f6415dc922a.pngModel description

      1750041376195449.png



      395181ccb7a771e30162f6415dc922a.pngM12 Connection cable selection

      M12 connection cable

      image.png

      Basic function cable(5-pin, 5-core)

      LMC3-52--XL-P55C3

      LMC3-52-XL-P55C5

      LMC3-52-XL-P55C10

      Standard-type cable(8-pin,8-core)

      LMC3-52-XL-P88C3

      LMC3-52-XL-P88C5

      LMC3-52-XL-P88C10

      High-function type cable(12-pin,10-core)

      LMC3-52-XL-P1210C3

      LMC3-52-XL-P1210C5

      LMC3-52-XL-P1210C10


      395181ccb7a771e30162f6415dc922a.pngIndicator light description

      image.png


      Indicator light name

      Light color

      Status

      Status description

      Status of OSSD

      Detection status of the actuator

      Large indicator light

      Green

      Light up

      In normal operation

      ON

      Detection status

      Green

      Flashing

      (high- speed)

      Switching coding level from low to high, or teaching the matcher

      OFF

      Detected matcher is incorrect

      Green

      Flashing

      Switching coding level from low to high, or teaching the matcher

      OFF

      Detected matcher is incorrect

      Red and green alternating

      Flashing

      (high- speed)


      An untaught actuator is detected when operating at "high" coding level

      OFF

      Detected matcher is incorrect

      Error during coding level switching

      Not fixed

      Red

      Light up

      Door is in open state.

      OFF

      Non-detection status

      Flashing

      (high- speed)


      Error state.The sensor detects an abnormality

      OFF

      Not fixed

      Turn off

      Power OFF

      OFF

      Not fixed

      OSSD indictor light

      Green

      Light up

      OSSD is on

      ON

      Detection status

      Flashing

      OSSD is on,but the door is in an unstable state such as half-open

      ON

      Detection status

      Red

      Light up

      OSSD is off

      OFF

      Not fixed

      Input indicator light

      Green

      Light up

      Safety input is on

      Not fixed

      Detection status

      Flashing

      Self- holding release waiting state(waiting for reset input)

      OFF

      Not fixed

      Turn off


      Safety input is OFF,or other states.

      OFF

      Detection status


      395181ccb7a771e30162f6415dc922a.pngTechnical parameter

      Model

      LMC3-52-J

      LMC3-52-B

      LMC3-52-G

      Type

      Basic function type

      Standard type

      High-function type

      Detection distance


      Front side

      sao(OFF→ON)

      10mm

      sar(ON→OFF

      18mm

      Side face

      sao(OFF→ON)

      6mm

      sar(ON→OFF

      14mm

      Response time(ms)*1

      Detection action

      Detection→Non-detection

      20ms+2ms×(total number of cascade-connected units -1)

      Non-detection→ Detection

      30ms+25ms×(total number of cascade-connected units-1)

      Door operation

      Allowable operating frequency

      3Hz

      Magnetic attraction

      Magnetic holding force

      15N

      Cascade connection

      Standard

      -

      Maximum 30 units

      Control output(OSSD output)

      Output type

      Transistor output×2

      Maximum load current

      PNP:<=150mA、NPN:<=100mA

      Residual voltage during ON state

      Maximum 2.5V(with 5m cable)

      Voltage in OFF state

      Maximum 2.0V(with 5m cable)

      Leakage current

      Maximum 0.5mA

      Maximum load capacity

      2.2μF

      Load wiring resistance

      Maximum 2.5Ω

      Detection distance

      Front side

      sao(OFF→ON)

      10mm

      sar(ON→OFF

      18mm

      Side face

      sao(OFF→ON)

      6mm

      sar(ON→OFF

      14mm

      Response time(ms)*1

      Detection action

      Detection→Non-detection

      20ms+2ms×(total number of cascade-connected units-1 )

      Non-detection→ Detection

      30ms+25ms×(total number of cascade-connected units-1 )

      Door operation

      Allowable operating frequency

      3Hz

      Magnetic attraction

      Magnetic holding force

      15N

      Cascade connection

      Standard

      -

      Maximum 30 units

      Control output(OSSD output)

      Output type

      Transistor output×2

      Maximum load current

      PNP:<=150mA、NPN:<=100mA

      Residual voltage during ON state

      Maximum 2.5V(with 5m cable)

      Voltage in OFF state

      Maximum 2.0V(with 5m cable)

      Leakage current

      Maximum 0.5mA

      Maximum load capacity

      2.2μF

      Load wiring resistance

      Maximum 2.5Ω

      AUX output(Non-safety system output)

      Output type

      Transistor output

      Number of outputs

      1

      Maximum load current

      50mA

      Residual voltage during ON state

      Maximum 2.5V(with 5m cable)

      External input (Short-circuit current)

      Safety input

      -

      Approximately 1.5mA×2

      Reset/EDM Input

      -

      Approximately 5mA×1

      Power supply

      Power supply voltage

      24VDC±20% including ripple(P-P)10%Class2

      Power comsuption

      0.8W*2

      Protection circuits

      Power reverse connection protection、each output short-circuit protection、eacn output surge protection、output reverse connection protection

      Safety related parameters

      ISO13849-1 IEC/EN60947-5-1 IEC/EN60947-5-3

      Compliant with ISO 13849-1 catagory 4 switch /suitable for PLe/PLd

      MTTFd≥30 years

      CE

      Environmental resistance

      Enclosure protection class

      IP65,IP67IP68 requires customization,pls consult the sales department before placing an order

      Operating ambient temperature

      -20℃ to +55℃(No freezing)

      Storage ambient temperature

      -25℃ to +70℃(No freezing)*3

      Operating ambient humidity

      5% to 95%RH

      Storage ambient humidity

      5% to 95%RH

      Vibration resistance

      10 to 55HZ、double amplitude 3.0mm、5 minutes for each directions X、Y、Z

      (IEC60947-5-3)

      Shock resistance

      30G,6 times for each direction X、Y、Z(IEC60947-5-3)

      Material

      Sensor

      Host server

      Housing

      Flame-retardant grade thermoplastic

      Cable

      PVC

      Matcher

      Housing

      Flame-retardant grade thermoplastic

      *1 The risk time specified in IEC60947-5-3 is 150 ms+2 ms×(total number of cascade-connected units-1) 

      *2 Excluding load current。

      *3 For long-term storage ,pls store in an environment below 55℃

      395181ccb7a771e30162f6415dc922a.pngProduct dimension drawing

      1750041793170171.png1750041831401457.png


      395181ccb7a771e30162f6415dc922a.pngWiring diagram

      1750042721223258.png

      Pin number

      Signal definition

      Color

      Description

      1

      24V

      Brown

      Positive power supply

      2

      OSSD2

      White

      safety output 2

      3

      0V

      Blue

      Negative power supply

      4

      OSSD1

      Black

      safety output 1

      5

      AUX output

      Gray

      Auxiliary output 1


      1750042818626171.png

      Pin number

      Signal definition

      Color

      Description

      1

      AUX output 1

      Gray

      Auxiliary output 1

      2

      24V

      Brown

      Positive power supply

      3

      Not used

      Red

      Not used

      4

      safety input 2

      Yellow

      Cascade input 2

      5

      OSSD1

      Black

      safety output 1

      6

      OSSD2

      White

      safety output 2

      7

      0V

      Blue

      Negative power supply

      8

      safety input 1

      Green

      Cascade input 1


      1750043082195521.png

      Pin number

      Signal definition

      Color

      Description

      1

      24V

      Brown

      Positive power supply

      2

      Safety input 1

      Green

      cascade input 1

      3

      0V

      Blue

      Negative power supply

      4

      OSSD1

      Black

      Safety output 1

      5

      AUX output1

      Gray

      Auxiliary output 1

      6

      Safety input 2

      Yellow

      cascade input 2

      7

      OSSD2

      White

      Safety output 2

      8

      Self-holding/EDM selection input

      Pink

      Self-holding/EDM selection input

      9

      Not used

      Red

      Not used

      10

      11

      Reset/EDM input

      Purple

      Reset/EDM input

      12

      1750045067392088.png1750045195573398.png1750045324661430.png
      Wiring example for cascade connection

      High-functioning self-protection function:

      圖片3.png

      The self-protection function is a feature that prevents the OSSD from automatically switching from OFF state to ON state. This function can prevent accidental startup or restart of the device. To restore from the state where the self-protection is active to the normal operating state, a reset operation is required.

      The basic function type and standard type can not set the self-protection function. The self-protection function is fixed to "Automatic"

      The self-protection function of high-function type can be selected from two types:"Automatic"and"Manual".

      "Automatic"and"Manual" here refer to following actions:

      Automatic:

      When the OSSD meets the condition for switching to the ON state(for example, the door is in the closed state), it shall switch to the ON state immediately.

      Manual:

      Even if the OSSD meets the condition for switching to the ON state, it shall remain in the OFF state(self-holding state).

      <Release of self-holding state>

      To switch the OSSD to the ON state and start the equipment, a reset operation must be performed under the conditions that the door with GS(non-contact)installed is closed and the equipment is ready for startup.Through this,the OSSD will switch to the ON state,and the self-holding state can be released.

      Setting of Self-holding function

      Self-holding function

      EDM function

      Reset/EDM input(Purple)

      Self-holding/EDM function selection input(Pink)

      Automatic

      Not in use

      0V

      0V

      Automatic

      in use

      Connect to 24 V via NC contact of relay

      Open

      Manual

      Not in use

      Connect to 24 V via NO reset switch

      Connect to 24 V

      Manual

      in use

      Connect to 24V via NO reset switch and NC contact of relay

      Connect to 24 V



      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh