      D3SL-E/RFID electromagnetic lock tongue locking safety door switch

      D3SL-E-黃色.png

      ·All structural appearance, strong, safe and resistant.

      ·Multi-function: it has the functions of mechanism locking and monitoring at the same time

      ·Multiple coding modes: only coding and general coding are optional.

      ·Single redundancy and double output: preventing potential safety hazards caused by single loop failure.

      ·Cascade connection of switches can reduce the number of transmission points.

      ·Skillful appearance: the cutting length is ?30mm*30mm.

      ·Flexible installation: it can be directly installed on an aluminum frame not exceeding 30 mm.


      Product selection table

      Locking mode

      Configuration type

      Coding type

      Output mode

      Lead mode

      Cable length

      model

      mechanical caging

      normalized form

      universal coding

      NPN

      Direct outlet

      3M

      D3SL-E-JB-2N-Z3

      5M

      D3SL-E-JB-2N-Z5

      10M

      D3SL-E-JB-2N-Z10

      M12 connector

      /

      D3SL-E-JB-2N-M12

      PNP

      Direct outlet

      3M

      D3SL-E-JB-2P-Z3

      5M

      D3SL-E-JB-2P-Z5

      10M

      D3SL-E-JB-2P-Z10

      M12 connector

      /

      D3SL-E-JB-2P-M12

      Unique coding

      NPN

      Direct outlet

      3M

      D3SL-E-JB-1N-Z3

      5M

      D3SL-E-JB-1N-Z5

      10M

      D3SL-E-JB-1N-Z10

      M12 connector

      /

      D3SL-E-JB-1N-M12

      PNP

      Direct outlet

      3M

      D3SL-E-JB-1P-Z3

      5M

      D3SL-E-JB-1P-Z5

      10M

      D3SL-E-JB-1P-Z10

      M12 connector

      /

      D3SL-E-JB-1P-M12

      mechanical caging

      high function

      universal coding

      NPN

      Direct outlet

      3M

      D3SL-E-JG-2N-Z3

      5M

      D3SL-E-JG-2N-Z5

      10M

      D3SL-E-JG-2N-Z10

      M12 connector

      /

      D3SL-E-JG-2N-M12

      PNP

      Direct outlet

      3M

      D3SL-E-JG-2P-Z3

      5M

      D3SL-E-JG-2P-Z3

      10M

      D3SL-E-JG-2P-Z1

      M12 connector

      /

      D3SL-E-JG-2P-M12

      Unique coding

      NPN

      Direct outlet

      3M

      D3SL-E-JG-1N-Z3

      5M

      D3SL-E-JG-1N-Z5

      10M

      D3SL-E-JG-1N-Z1

      M12 connector

      /

      D3SL-E-JG-1N-M12

      PNP

      Direct outlet

      3M

      D3SL-E-JG-1P-Z3

      5M

      D3SL-E-JG-1P-Z5

      10M

      D3SL-E-JG-1P-Z1

      M12 connector

      /

      D3SL-E-JG-1P-M12

      Electromagnetic locking

      normalized form

      universal coding

      NPN

      Direct outlet

      3M

      D3SL-E-DB-2N-Z3

      5M

      D3SL-E-DB-2N-Z5

      10M

      D3SL-E-DB-2N-Z10

      M12 connector

      /

      D3SL-E-DB-2N-M12

      PNP

      Direct outlet

      3M

      D3SL-E-DB-2P-Z3

      5M

      D3SL-E-DB-2P-Z5

      10M

      D3SL-E-DB-2P-Z10

      M12 connector

      /

      D3SL-E-DB-2P-M12

      Unique coding

      NPN

      Direct outlet

      3M

      D3SL-E-DB-1N-Z3

      5M

      D3SL-E-DB-1N-Z5

      10M

      D3SL-E-DB-1N-Z10

      M12 connector

      /

      D3SL-E-DB-1N-M12

      PNP

      Direct outlet

      3M

      D3SL-E-DB-1P-Z3

      5M

      D3SL-E-DB-1P-Z5

      10M

      D3SL-E-DB-1P-Z10

      M12 connector

      /

      D3SL-E-DB-1P-M12

      Electromagnetic locking

      high functionuniversal codingNPNDirect outlet

      3M

      D3SL-E-DG-2N-Z3

      5M

      D3SL-E-DG-2N-Z5

      10M

      D3SL-E-DG-2N-Z1

      M12 connector

      /

      D3SL-E-DG-2N-M12
      PNPDirect outlet

      3M

      D3SL-E-DG-2P-Z3

      5M

      D3SL-E-DG-2P-Z5

      10M

      D3SL-E-DG-2P-Z10
      M12 connector/D3SL-E-DG-2P-M12
      Unique codingNPNDirect outlet

      3M

      D3SL-E-DG-1N-Z3

      5M

      D3SL-E-DG-1N-Z5

      10M

      D3SL-E-DG-1N-Z10

      M12 connector

      /

      D3SL-E-DG-1N-M12

      PNPDirect outlet

      3M

      D3SL-E-DG-1P-Z3

      5M

      D3SL-E-DG-1P-Z5

      10M

      D3SL-E-DG-1P-Z10
      M12 connector

      /

      D3SL-E-DG-1P-M12



      Model description

      1732760511358034.png


      Fitting selection

      category

      Product chart

      name of an article

      model

      Actuator

      1732760887771255.png

      Pass code actuator

      DF-K2

      Code-only actuator

      DF-K1

      Mounting frame

      1732760908750158.png

      Rotating shaft mounting frame

      (Hinged and closed type suitable for opening to the left)

      D3SL-E-ZJ-JL-L

      1732760923676437.png

      Rotating shaft mounting frame

      (Hinged and closed type suitable for opening to the right)

      D3SL-E-ZJ-JL-R

      1732760916984883.png

      Sliding mounting frame

      (Push-pull type suitable for opening to the left)

      D3SL-E-ZJ-TL-L

      1732760943568836.png

      Sliding mounting frame

      (Push-pull type suitable for opening to the right)

      D3SL-E-ZJ-TL-R

      M12 connecting line

      1732761048242779.png

      Standard cable (8 pins)

      D3SL-E-XL-P8C3

      D3SL-E-XL-P8C5

      D3SL-E-XL-P8C10

      Functional cable (12 pins)

      D3SL-E-XL-P12C3

      D3SL-E-XL-P12C5

      D3SL-E-XL-P12C10

      Safety latch

      圖片2.pngSafety latch BS06

      RFID electromagnetic lock+safety latch

      圖片2.png

      圖片2.png


      technical parameter

      standard

      ISO13849-1(Category 4/PLe);IEC/EN60947-5-3

      authentication

      CE

      Locking mode

      Electromagnetic locking/mechanical locking

      Safe output

      NPN*2/PNP*2

      Response time

      Lock → Unlock

      100ms(獨立工作)

      Unlock → Lock

      鎖定

      Locking retention force Fzh

      ≥2000N

      Latch insertion deviation

      ≤2mm

      Mechanical durability

      >1 million times (door operation speed 1m/s)

      Operating frequency

      1Hz

      Minimum service radius of revolving door

      ≥220mm

      Manual unlocking

      Front and back

      Cascade connection

      Up to 20 sets

      Control output (OSSD

      Output)


      Output type

      Transistor output ×2

      Maximum load current

      ≤200mA

      Residual voltage (ON)

      <2.5V@200mA

      OFF voltage

      ≤2V@線纜5m

      leakage current

      ≤0.5mA

      Maximum load capacity

      2.2uF

      Load connection resistance

      ≤2.5Ω

      AUX

      Output (non-secure output)


      Output type

      Transistor output

      Output quantity

      1

      Maximum load current

      50mA

      Residual voltage (ON)

      ≤2.5V@50mA

      External transmission

      (Open circuit current)

      Safety input

      1.5mA*2

      Reset /EDM input

      約10mA*1

      Lock control input

      約10mA*1

      Power Supply 

      Working voltage

      DC24V±15%

      rated power

      4.6W(空載)

      protect

      Safety circuit breaker protection, current limiting, overload protection, overvoltage protection, overheating protection stop and restart, reverse polarity protection, transient noise protection and failure pulse protection.

      Environmental resistance

      patience


      Enclosure protection grade

      IP65

      Action ambient temperature

      -20℃~55℃(No freeze)

      Storage ambient temperature

      -25℃~70℃(No freeze)

      Humidity of action environment

      5%~95%RH

      Storage environment humidity

      5%~95%RH

      Vibration resistance

      10至55Hz、雙振幅2.0mm、X、Y、Z各方向5分鐘(IEC60947-5-3)

      shockproof

      30g X、Y、Z各?向6次(IEC60947-5-3)

      Risk time

      100ms

      start time

      3.5s

      texture of wood

      Nylon/zinc alloy/stainless steel


      Indicator light description

      1732762228332084.png

      Indicator name

      Lighting color

      State description

      Output indicator lamp

      Red and green

      1.OSSD output: green

      2.OSSD off: red

      3.OSSD error: red flashing (2Hz)

      4.EDM error: red flashing (1Hz)

      Input indicator light

      yellow

      1. Normal input: lit

      2. Lose (waiting to lose): put out.

      3. Wait for RSET reset: 1Hz flashing.

      Lock indicator light

      green

      1. Locking: Lighting

      2. Abnormal locking: 2Hz flashing (electromagnet error, optocoupler error)

      3. RFID: 1 Hz flashing

      4. Unlocked: Off


      Status indicator lamp

      Red and green

      1. Lock and output: green light

      2. Output: red light

      3. Voltage error: the red light flashes for 2Hz.

      4. Internal fault detection error: the red light flashes at 1Hz.

      5. Error in checking internal data: the green light flashes at 1Hz.


      Product dimension diagram


      圖片3.png


      圖片4.png


      Installation diagram

      圖片5.png圖片7.png

      Slide the mounting bracket D3SL-E-ZJ-TL-R (open to the right)

      Sliding installation of D3SL-E and DF-K

      Slide mounting frame D3SL-E-ZJ-TL-L (open to the left)

      Sliding installation of D3SL-E and DF-K

      圖片8.png圖片9.png


      hookup

      Standard type (NPN, no cascade)

      Standard (PNP, no cascade)

      圖片14.png

      Standard type (NPN, cascade)

      圖片15.png

      Standard type (NPN, cascade)

      圖片16.png

      Advanced type (NPN, no cascade)

      High functional type (PNP, no cascade)
      圖片17.png

      High functional type (NPN, cascade)

      圖片18.png

      High functional type (PNP, cascade)

      圖片19.png


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh