      LGY-300 long-distance laser ranging sensor 300 meters
      1726048288130717.png


      ·Visible red laser, easy to align and debug

      ·Support the movement speed of 10m/s.

      ·Support SSI, PROFINET, MODBUS RTU, RS422 and other interface outputs.

      ·TOF measurement principle ensures ultra-fast measurement speed and ultra-fast measurement frequency.

      ·High precision, which can better locate the position of moving objects accurately.



      Product selection table

      working distance

      precision

      frequency

      joggle/interface

      Working temperature

      model

      0.2-100m

      ±2mm

      200Hz

      RS422

      –10℃...+50℃

      LGY-300-S

      200Hz

      MODBUS RTU, RS232

      LGY-300-MS

      400Hz

      SSI, RS232

      LGY-300-ES

      400Hz

      PROFINET, RS232

      LGY-300-NS

      200Hz

      RS422

      –40℃...+50 ℃

      LGY-300H-S

      200Hz

      MODBUS RTU, RS232

      LGY-300H-MS

      400Hz

      SSI, RS232

      LGY-300H-ES

      400Hz

      PROFINET, RS232

      LGY-300H-NS


      technical parameter

      performance parameter

      measuring range

      0.2…300m

      precision

      ±2mm(90%reflectivity)@2σ

      repeatability

      0.3mm

      Measuring frequency

      200Hz

      resolution ratio

      0.1mm

      Measuring object

      Reflective film

      Laser spot

      6mm(10m)

      Laser light source

      Red laser

      wavelength:650–690nm

      Pulse duration:3ns

      Beam divergence:0.16×0.6mrad

      Laser power:0.95mW

      Laser grade

      Secondary laser


      IEC 60825-1:2014, EN 60825-1:2014


      Laser lifetime

      100'000h @ 25℃


      Interface parameters

      PROFINET

      Network load level

       II

      function

      Measurement data output, parameter setting

      RS-232

      Baud rate

      115200

      data bit

      8

      Stop position

      1

      Check Digit

      fluid control

      function

      Measurement data output, parameter setting

      Mechanical/electronic parameters

      supply voltage

      DC 18V…30V

      power

      <3.5W (在24VDC)

      Initialization time

      Typ. 5s

      Connection type

      A code 5-pin M12 plug

      sheathing material

      D-coded 4-pin M12 plug

      Aluminum die casting

      the protection grades

      IP65

      weight

      975g

      measure

      129*69.5*92mm

      Working temperature

      -10℃…+50℃

      Storage temperature

      -25℃…+75℃

      Electromagnetic compatibility (wireless)

      EN 55032:2015,EN61000-3-2:2014,EN 61000-3-3:2013,

      EN 55035:2017


      Schematic diagram of pin distribution and wiring

      1727666167173632.png1727666271945721.png


      Error code description

      If there is an error code not listed in the table below, please contact our technical support.

      serial number

      format

      meaning

      debugging

      1

      @E203

      Wrong command or parameter

      Check input instructions, parameters and communication settings.

      2

      @E220

      Communication error

      Check and eliminate electromagnetic interference around sensors and communication lines.

      3

      @E234

      no to scale

      Adjust the distance of the measured target to make it within the measuring range.

      4

      @E252

      The temperature is too high

      Reduce the ambient temperature. If an error occurs at room temperature, please contact our technical support

      5

      @E253

      The temperature is too low.

      Raise the ambient temperature. For sensors with heating function, wait for the heating temperature to rise. If an error occurs at room temperature, please contact our technical support

      6

      @E255

      The received signal is too weak

      Improve the reflectivity of the measured target.

      7

      @E256

      The received signal is too strong

      Reduce the reflectivity of the measured target.

      8

      @E257

      The background light is too noisy

      Eliminate the clutter of background light

      9

      @E260

      There are multiple targets in the measurement, so it is impossible to measure the distance.

      Determine the distance of the measured target and eliminate the phenomenon of target distance jump.

      10

      @E289

      Contact our technical support.

      /


      Sensor indicator description

      The sensor status and PROFINET interface status are displayed by LED lights as described in the following table.

      LED

      explain

      Possible cause of abnormality

      debugging

      Port2

      PROFINET interface 2

      LED lights green: normal operation

      LED off: the connection is disconnected.

      The device did not shake hands with the master station.

      The sensor is damaged.

      Contact our technical support.

      Port1

      PROFINET interface 1

      LED lights green: normal operation

      LED off: the connection is disconnected.

      The device did not shake hands with the master station.

      The sensor is damaged.

      Contact our technical support.

      Power(Error)

      Sensor status

      The LED lights green: the sensor is normal.

      The LED is red: the sensor is abnormal.

      Not running.

      The sensor is damaged.

      Check the operating voltage.

      Check the corresponding error code and eliminate the exception as instructed.

      Contact our technical support.


      Product outline dimension diagram


      1725588876571101.png


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh