      Welcome to the official website of Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.!
      Position首頁(yè) > Home > Industrial Safety Products > Sensor > Laser Distance Sensor > 激光測(cè)距傳感器 短距離(1)
      Laser displacement sensor short distance
      1725513652834177.png

      ·5 micron repetition accuracy

      ·Bring your own 485 communication

      ·Accurately detect the relative displacement of the object to be measured.

      ·Used for measuring physical quantities such as length, distance, vibration, speed and orientation.


      Product introduction

      Micron-scale repetition accuracy

      Tested by laser interferometer, the repeatability is 5Um.

      485 communication

      Support 485 communication, which can replace imported brands.

      Non-contact measurement

      Non-contact measurement, metal and plastic can be detected.

      Ultra high precision

      Ultra-high precision, can measure tiny objects.


      usage scenario

      Laser displacement sensor is suitable for lithium battery, printing and packaging, coating machine, intelligent manufacturing and other industries, and is often used to measure physical quantities such as length, height, width, distance, vibration, speed, orientation, object presence, shape and flatness.


      Product parameter

      Product parameterMeasuring center 30mm typeMeasuring center 50mm typeMeasuring center 100mm typeMeasuring center 200mm typeMeasuring center 400mm type

      Model name (Note 2)

      NPN output

      LDS-H030NA

      LDS-H050NA

      LDS-H100NA

      LDS-H200NA

      LDS-H400NA

      LDS-H030N-C

      LDS-H050N-C

      LDS-H100N-C

      LDS-H200N-C

      LDS-H400N-C

      PNP output

      LDS-H030PA

      LDS-H050PA

      LDS-H100PA

      LDS-H200PA

      LDS-H400PA

      LDS-H030P-C

      LDS-H050P-C

      LDS-H100P-C

      LDS-H200P-C

      LDS-H400P-C

      Measuring center distance30mm50mm100mm200mm400mm
      measuring range±5mm±15mm±35mm±80mm±200mm
      repeatability5μm20μm40μm100μm300μm(measure a distance 200-400mm)
      600μm(measure a distance 400-600mm)
      Black and white surface error10μm40μm100μm300μm1mm
      linearity±0.1%F.S.±0.2%F.S.±0.3%F.S.

      Measuring speed

      100-2000Hz

      Communication output

      RS-485

      Laser wavelength

      Red semiconductor laser, class 2 [JIS/IEC/GB/FDA] Maximum output: 1mW, wavelength of emission peak. :650nm

      Beam diameter

      appointment Φ100μm
      appointment Φ180μm
      appointment Φ250μm
      appointment Φ400μm
      appointment Φ700μm

      Temperature characteristics

      0.03%F.S./°C

      light source

      Red semiconductor laser Class 2 (JIS/IEC/GB)/Class II (FDA) (Note 3)

      Maximum output: 1mW, wavelength of luminous beam: 655nm.

      Power supply voltage

      12V~24V DC±10% pulsation P-P10%

      Consumption current

      Less than 40mA (when the power supply voltage is 24V DC) and less than 60mA (when the power supply voltage is 12V DC).

      Control output

      <NPN output type >

      NPN open collector transistor

      Maximum inflow current: 50mA

      Applied voltage: below 30V DC (control output is between -0V).

      Residual voltage: less than 1.5V (with inflow current of 50mA)

      Leakage current: less than 0.1mA


      <PNP output type >

      PNP open collector transistor

      Maximum source current: 50mA

      Applied voltage: below 30V DC (between-+V for control output)

      Residual voltage: less than 1.5V (with an outflow current of 50mA)

      Leakage current: less than 0.1mA

      Output action

      ON in light/on in non-light can be switched.

      Short circuit protection

      Equipped (automatic recovery type)

      analog output

      Output range: 0v ~ 5v (++5.2V in case of alarm)

      Output impedance: 100 ω

      Reaction time

      0.5ms/1ms/1.5ms/5ms/10ms

      external input

       <NPN output type >

      NPN contactless input

      Input conditions

      Invalid:+8V ~+V DC or open

      Effective: 0v ~+1.2vdc.

      Input impedance: about 10kΩ.

      < <PNP output type >

      PNP contactless input

      Input conditions

      Invalid: 0v ~+0.6vdc or open.

      Effective:+4v ~+vdc

      Input impedance: about 10kΩ.

      Protective structure

      IP67(IEC)

      Degree of fouling

      2

      Operating ambient temperature

      -10℃ ~ +50℃

      Use ambient illumination

      Shouguang surface illumination 3000Lux below

      Using ambient humidity

      35%~85%RH

      Use elevation

      2,000m below

      electric cable

      belt 0.2mm2 5-core composite cable 2m

      texture of wood

      Body shell: aluminum casting front cover: propylene-based.

      weight

      Body shell: aluminum casting front cover: propylene-based.

      Applicable specifications

      Comply with EMC directives and FDA rules.

      (Note 1): When the measurement conditions are not specified, the use conditions are as follows: power supply voltage: 24V DC, ambient temperature:+20℃, reaction time: 10ms, and analog output value of measurement center distance. Object: white ceramics.

      (Note 2): Model A is analog voltage version, and Model -C is communication version.

      (Note 3): According to Laser Notice No.50 in FDA rules, abide by FDA rules.




      Product outline dimension diagram

      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing