      SM1002 programmable safety controller
      As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

      (1) Redundancy

      (2) Difference

      (3) Self-detection



         How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.

      SM-1002 programmable controller

      1002.png

      ·Is a configurable safety controller, which supports the input of various safety product components.

      ·Maximum support for 10 groups of dual-loop inputs.

      ·4-channel semiconductor safety output, expandable output module

      ·Input and output fault indicator light

      ·Safety certification: PL e, Cat: 4



      395181ccb7a771e30162f6415dc922a.pngProduct selection

      product name

      model

      Safety input

      Safe output

      brand

      Safety controller

      SM-1002

      10CH

      4SO

      LHS

      explain

      You can enter up to 10 sets of dual-channel security products.

      Safety grating, emergency stop, safety door lock, reset, etc.

      Official website programming software download connection.:http://lhsafety.com.cn/showinfo-257-118-0.html


      395181ccb7a771e30162f6415dc922a.pngsafety performance

      ? Performance level (PL): PL e

      ? Security category (Cat.): Cat.4

      ? Mission time (TM): 20 years

      ? Diagnostic coverage (DC/DC avg): 99%

      ? Safety Integrity Level (SIL): SIL3

      ? Hardware Fault Margin (HFT): 1

      ? Safe Failure Score (SFF): 99%

      ? Probability of dangerous failure (PFH d): 1.78E-9/h

      ? Stop Category: 0/1

      Complies with standard EN ISO13849

      Complies with standard EN ISO13849

      Complies with standard EN ISO13849

      Complies with standard EN ISO13849

      Conforms to standards IEC61508, IEC62061

      Conforms to standards IEC61508, IEC62061

      Conforms to standards IEC61508, IEC62061

      Conforms to standards IEC61508, IEC62061

      Complies with standard EN 60204-1

      395181ccb7a771e30162f6415dc922a.pngMain technical parameters

      Power supply characteristics

      ·Power supply voltage: 24VDC

      ·Voltage range: 20~30VDC

      ·Current loss: ≤35mA(24VDC)

      Input characteristics

      ·Input current: ≤10mA(24VDC)

      ·Conductor resistance: ≤15Ω

      ·Input equipment: emergency stop button, safety door, two-hand button, safety light curtain,

                         Heartbeat sensor, etc

      ·Input channel: 10

      Relay output characteristics

      ·Number of contacts: 4SO (safety output)

      ·Contact fuse protection: 5A is fast, 3A is slow.

      ·Switching capacity: 2A/24VDC

      Semiconductor output characteristics

      ·Number of contacts: 4SO (safety output)

      ·Contact fuse protection: 10A is fast, 6A is slow.

      ·Switching capacity: 2A/24VDC

      Time characteristic

      ·Suction buffer time: ≤100ms

      ·Release buffer time: ≤30ms

      ·Recovery time:

               Emergency stop operation: ≤30ms

               Power failure: ≤1000ms

      ·Short-term power interruption: 20ms

      control logic

      ·Control logic: 10 kinds of logic, and new logic can be customized according to customer requirements.

      ·Delay setting time: 0s~99s

      ·Heartbeat monitoring frequency: 0.1Hz~10Hz

      ·Frequency output logic block: 0.1Hz~10Hz


      395181ccb7a771e30162f6415dc922a.pngEnvironmental characteristic parameters

      ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

      ·Vibration frequency: 10Hz~55Hz

      ·Vibration amplitude: 0.35mm

      ·Operating temperature: -20℃~+60℃

      ·Storage temperature: -40℃~+85℃

      ·Relative humidity: 10%~90%

      ·Overvoltage grade: Ⅲ

      ·Pollution level: 2

      ·Altitude: ≤2000m

      ·Electrical clearance and creepage distance: in accordance with EN60947-1.

      1002.png


      395181ccb7a771e30162f6415dc922a.pngFunctional application parameters

      功能框圖

      典型應用

      圖片3.png

      30d4fa1676811c3a6977a8358764a55.png


      輸入元件:CH1(急停按鈕);CH2(急停按鈕);

                     CH3 (急停按鈕)

      輸入元件:CH7(急停按鈕);CH8(急停按鈕)

                     CH10(復位按鈕)

      控制邏輯:CH1&CH2&CH3      

      復位方式:手動復位   輸出延時:0s

      安全等級:Cat.4     性能等級:PLe    

      安全完整性等級:SIL3


      395181ccb7a771e30162f6415dc922a.png

      Wiring diagram

      Power Supply 

      1.png

      input

      2.png3.png4.png
      5.png6.png7.png
      8.png9.png

      reset

      10.png11.png

      feedback

      12.png13.png

      output

      14.png15.png


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh