      SM-602 programmable safety controller

      As the most important part of safety loop, safety controller/safety PLC has been recognized by more and more people, but in the process of use, there are still many users who are confused about the differences between safety relay and ordinary relay, so I would like to share them with you here. As we all know, we must remember three words in the concept of safety design:

      (1) Redundancy

      (2) Difference

      (3) Self-detection


         How to construct the safety loop with the reliability above PLd, the safety controller must become an important link. The safety loop consists of safety input, safety control and safety output subsystems, and the safety control "including safety relay, safety controller, safety PLC, etc." realizes the safety control function. Designers match different safety controllers to achieve the reliability level of the safety loop according to the number of products at the input end.


      SM-602 programmable safety controller

      1720164449995785.png

      Is a configurable safety controller, which supports the input of various safety product components.

      Maximum support for 6 sets of dual-loop inputs.

      2-way safety relay output

      4-channel semiconductor safety output, expandable output module

      Modbus protocol communicationInput and output fault indicator light

      Safety certification: PL e, Cat: 4


      Product selection

      product name

      Type number

      Safe input

      Output

      Brand

      Safety controller

      SM-602

      6CH

      2NO+4SO

      LHS

      explain

      Up to 6 sets of dual-channel safety products can be entered.

      Safety grating, emergency stop, safety door lock, reset, etc.

      Official website programming software download connection: http://lhsafety.com.cn/showinfo-257-118-0.html








      safety performance

      ? Performance level (PL): PL e

      ? Security category (Cat.): Cat.4

      ? Mission time (TM): 20 years

      ? Diagnostic coverage (DC/DC avg): 99%

      ? Safety Integrity Level (SIL): SIL3

      ? Hardware Fault Margin (HFT): 1

      ? Safe Failure Score (SFF): 99%

      ? Probability of dangerous failure (PFH d): 1.78E-9/h

      ? Stop Category: 0/1

      Complies with standard EN ISO13849

      Complies with standard EN ISO13849

      Complies with standard EN ISO13849

      Complies with standard EN ISO13849

      Conforms to standards IEC61508, IEC62061

      Conforms to standards IEC61508, IEC62061

      Conforms to standards IEC61508, IEC62061

      Conforms to standards IEC61508, IEC62061

      Complies with standard EN 60204-1


      Main technical parameters

      Power supply 

      characteristics

      ·Power supply voltage: 24VDC

      ·Voltage range: 20~30VDC

      ·Current loss: ≤110mA(24VDC)

      Input characteristics

      ·Input current: ≤10mA(24VDC)

      ·Conductor resistance: ≤15Ω

      ·Input equipment: emergency stop button, safety door, two-hand button safety light curtain, magnetic safety switch, etc.

      ·Input channel: 6

      Relay output 

      characteristics

      ·Number of contacts: 2NO (safety output)

      ·Contact material: AgSnO2

      ·Contact fuse protection: 10A is fast, 6A is slow.

      ·Switching capacity: 5A/230VAC;; 5A/24VDC

      Semiconductor output characteristics

      ·Number of contacts: 4SO (safety output)

      ·Contact fuse protection: 10A is fast, 6A is slow.

      ·Switching capacity: 2A/24VDC

      Time characteristic

      ·Suction buffer time: ≤100ms

      ·Release buffer time: ≤30ms

      ·Recovery time:

               Emergency stop operation: ≤30ms

               Power failure: ≤1000ms

      ·Recovery time:

               Emergency stop operation: ≤30ms

               Power failure: ≤100ms

      ·Short-term power interruption: 20ms

      Communication 

      characteristics

      ·Baud rate: 38.4kbps (fixed)

      ·Communication length: ≤1000m

      ·Networking capacity: ≤10 units


      Environmental characteristic parameters

      ·Electromagnetic compatibility: comply with EN60947, EN61000-6-2 and EN61000-6-4.

      ·Vibration frequency: 10Hz~55Hz

      ·Vibration amplitude: 0.35mm

      ·Service temperature: -20℃~+60℃

      ·Storage temperature: -40℃~+85℃

      ·Relative humidity: 10%~90%

      ·Overvoltage grade: Ⅲ

      ·Pollution level: 2

      ·Altitude: ≤2000m

      ·Rated isolation voltage: 250VAC.

      ·Rated impulse voltage: 6000V(1.2/50us)

      ·Insulation strength: 1500VAC, 1min.

      ·Electrical clearance and creepage distance: in accordance with EN60947-1.

      1666333314320610.png


      Functional application parameters

      functional block diagram

      Typical application

      圖片3.png

      圖片4.png


      Input element: CH1 (emergency stop button); CH2 (emergency stop button); CH3 (reset button)

      Input element: CH4 (emergency stop button); CH5 (emergency stop button); CH6 (reset button)

      Control logic: CH1&CH2CH4&CH5

      Reset mode: manual reset output delay: 0s.

      Safety level: Cat.4 performance level: PLe safety integrity level: SIL 3


      Wiring diagram

      Power Supply 

      1.png

      correspondence

      1655948458157829.png

      input

      3.png4.png5.png
      6.png7.png
      9.png10.png

      reset

      11.png12.png

      feedback

      13.png14.png

      output

      15.png16.png17.png


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh