      D3NL安全門鎖

      1748421026529267.gifimage.png

      The shape is square.
      The metal switch head can be adjusted in four directions.
      The spring force is released by the electromagnetic coil excitation to unlock.
      It is equipped with a standard auxiliary unlocking mechanism.
      The independent circuit indicator light can be used for various purposes.
      It has six built-in contacts that can be wired in various ways.


      395181ccb7a771e30162f6415dc922a.png

      Ordering Information

      1588126326899852.png

      Switch model

      Locking/releas method

      Material

      Conduit opening/connector

      D3NL-D 4NC+2NO

      Electromagnetic locking/mechanical release

      Metal

      M20

      D3NL-D 2NC/1NO+2NC/1NO

      Electromagnetic locking/mechanical release

      Plastic

      M20

      D3NL-J 2NC/1NO+2NC/1NO

      Mechanical locking/electromagnetic release

      Plastic

      M20

      D3NL-D 3NC+2NC/1NO

      Electromagnetic locking/mechanical release

      Plastic

      M20

      D3NL-J 3NC+2NC/1NO

      Mechanical locking/electromagnetic release

      Plastic

      M20

      D3NL-D 2NC/1NO+3NC

      Electromagnetic locking/mechanical release

      Plastic

      M20

      D3NL-J 2NC/1NO+3NC

      Mechanical locking/electromagnetic release

      Plastic

      M20

      D3NL-D 3NC+3NC

      Electromagnetic locking/mechanical release

      Plastic

      M20

      D3NL-J 3NC+3NC

      Mechanical locking/electromagnetic release

      Plastic

      M20

      Model

      Material

      Wiring diagram

      Operation mode

      Door monitoring

      Lock monitoring

      圖片3.png:Contact ON

      圖片4.png:Contact OFF

      D3NL-D 4NC+2NO

      Metal

      圖片1.png圖片2.png

      Model

      Material

      Door monitoring

      Lock monitoring

      圖片3.png:Contact ON

      圖片4.png:Contact OFF

      /

      /圖片5.png圖片6.png

      D3NL-D 2NC/1NO+2NC/1NO

      Plastic

      圖片7.png圖片8.png

      D3NL-J 2NC/1NO+2NC/1NO

      D3NL-D 3NC+2NC/1NO

      圖片9.png圖片10.png

      D3NL-J 3NC+2NC/1NO

      D3NL-D 2NC/1NO+3NC

      圖片11.png圖片12.png

      D3NL-J 2NC/1NO+3NC

      D3NL-D 3NC+3NC

      圖片13.png圖片14.png

      D3NL-J 3NC+3NC

      Handle Type

      Product Name

      Safety bolt

      Model

      BS11

      Type

      Ordinary handle

      Configure the door lock

      D3NL series

      Picture

      微信圖片_20250717163408.png1753759846183229.png


      395181ccb7a771e30162f6415dc922a.png

      Locking tongue type

      Direct-Insertion Mounting Type Z

      Long-L Mounting Type ZL

      Wide-Mount Type K

      Short-L Mounting Type KL

      Movable Installation Type H

      1729840307560035.png

      1729840299401164.png

      1729840292591645.png

      1729840281454281.png1729840240521860.png


      395181ccb7a771e30162f6415dc922a.png

      Contact Capacity

      Rated Voltage

      30V

      250V

      Rated Current

      AC

      Resistive LoadAC-12

      4A

      Inductive LoadAC-15

      2A

      DC

      Resistive LoadDC-12

      2A

      0.8A

      Inductive LoadDC-13

      1A

      0.4A


      395181ccb7a771e30162f6415dc922a.png

      Performance

      Security 

      Certificate

      Mechanical reliability

      B10d = 2.5×10? operating at a load of 100 mA.

      According to ISO 13849-1, up to Performance Level e (PLe), depending on the system architecture.

      According to EN 62061, up to SIL 3, depending on the system architecture

      Safety data

      8 cycles per hour, 24 hours per day, 365 days per year. MTTFd is 356 years

      Protection Rating

      IP67

      Service Life*1

      Mechanical

      No less than 1 million times

      No less than 100000 times(AC-12 250V 4A)

      Electrical

      No less than 1 million times(24V AC/DC 100mA)

      Operation progress

      0.5m/s

      Operation frequency

      Maximum 30次/min

      Forced disconnection force*2

      Minimum 60N

      Forced disengagement of travel*2

      Minimum 10mm

      Minimum applicable load

      24V DC 4mA

      Degree of pollution (operating environment)

      Pollution Degree 3

      Contact Capacity

      24V(DC13 4A)/230V (DC15 4A)

      With Electromagnetic Coil

      Rated Voltage:DC 24V

      Rated Current:0.4A

      Insulation Class:Class B

      Ambient Temperature

      -5-40℃


      395181ccb7a771e30162f6415dc922a.png

      Model and contact composition

      Model

      Contact Configuration:
      (Door Open/Close Detection Switch + Lock Monitoring Switch)

      Contact Form

      Action Mode

      D3NL

      4NC+2NO

      1729842125538672.png1729840754268178.png


      395181ccb7a771e30162f6415dc922a.png

      Magnetic Coil

      rated voltage

      DC24V+10%

      rated current

      0.4A

      insulation grade

      Class B


      395181ccb7a771e30162f6415dc922a.png

      External Dimensions and Installation Size

      Dimensions

      Installation Size

      1729841002944621.png1729840938381995.png


      395181ccb7a771e30162f6415dc922a.png

      Head Installation Direction

      Installation Direction

      Head Direction Adjustment

      1729841172713937.png1729841148346537.png

      The head of the safety door switch can be adjusted in direction to accommodate a wider range of installation environments. The housing position remains unchanged; only the direction of the head is altered.


      395181ccb7a771e30162f6415dc922a.png

      Auxiliary Unlocking Instructions

      1729843883103077.png

      When the safety door switch is operating normally, the arrow points to the "Locked" mark, and the anti-rotation screw must be in a tightened state. In special circumstances such as equipment power-off or malfunction, if it is necessary to open the guard door, the screw next to the arrow knob should be loosened first. Then, use a tool to turn the arrow knob to the "Unlocked" mark. At this point, the safety door switch is unlocked, the latch pin can be removed, and the guard door can be opened.


      395181ccb7a771e30162f6415dc922a.png

      Example Wiring Diagram for Safety Door Lock

      1729843453389468.png

      Product Name

      Model

      Safety Input

      Output

      Safety Relay

      SR-103 Series

      1 Set of Safety Products

      3NO+1NC

      Safety Controller

      SM-302 Series

      3 Set of Safety Products

      2NO

      Safety Controller

      SM-602 Series

      6 Set of Safety Products

      2NO+4SO

      Instructions

      Input product

      Emergency Stop Button,Safety door lock、Two-Hand Control Button、Safety curtain、Reset, etc.


      Related Products
      Download
      PDF file download
      Video file download
      Previous

      Contact us

      400-881-6062

      Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.

      E-Mail: info@lh-safety.com

      Address: 581 Xiuchuan Road, Chuansha Town, Pudong New District, Shanghai

      (Greenland East Coast International Plaza-Room A 313)

      Copyright ? Lihong Safety Equipment Engineering (Shanghai) Co., Ltd.  ICP19034341-1  Technical Support: lanjujing

      Online service

      Online message

    1. Click to refresh